Air Brakes   Aluminium Castings  ABS SW Design Centre

Home | About Us | Careers | Investor Information | Press Release | Contact Us  

 

 
1.00 Problem: Air is not building up in both the guages
1.10
Compressor
Cylinder head gasket failure.
Overhaul cylinder head.Also check for any block in pipe lines, hose and ULVTI filter. Remove blockage, clean filter and refit.

1.11

Hose, pipes & fittings

Heavy leak in circuit between compressor delivery and system protection value inlet.

Check lines & all joints. Rectify & replace hose assy if damaged.

1.12

Unloader value with TI (ULVTI)

Heavy leak through top cover & ex-spout.

Overhaul assembly.

1.13

Sensing reservoir

Heavy leak through weld joints or drain valve.

Rectify weld joint. Replace defective drain valve.

1.14
Air Filter
Heavy leak through cover.

Overhaul assembly.

1.15

System protection value


Heavy external leak from the value assembly.

Overhaul assembly.